Explosive Bolts

Explosive Bolts are used to firmly attach mating items and then allow remote separation on command.eboltimg

CAD Explosive Bolts come in two general types: fragmenting and non-fragmenting. The former, while more compact and economical, can produce a small amount of fragmentation and do liberate the products of combustion of the pyro/explosive material used. Non-fragmenting bolts separate cleanly without fragmentation and contain all products of combustion. CAD’s Undersea-capable bolts are typically of the non-fragmenting type.

CAD Explosive Bolts are manufactured using a wide range of materials, which can be selected to maximize strength and corrosion resistance and/or minimize weight or electrical conductivity.

As with our other pyrotechnically powered devices, a small amount of electrical energy can liberate a large amount of chemical energy and translate this to a large amount of mechanical work.

Applications:

  • On-Command separation of stages/sections on aerospace vehicles.
  • Release of payload and/or stores on air vehicles.
  • Release of payload, malfunctioning manipulator arms, ballast plates, etc. on undersea vehicles (Manned or Remotely Operated).

Performance:

  • Tensile strengths from 300 to 85,000 lbs-Force.
  • Materials cut: Fiber Optics; Stainless Steel Wire Rope; Armored Composite Tether; Steel, Stainless Steel, Titanium, etc. Structural Members.
  • Operating Temperatures of -65° F. to 420° F. (-54° C. to 215° C.)
  • Undersea Applications rated to 15,000 PSI.
  • Materials: Stainless Steel, Inconel, Plated Carbon Steel and Plastic.
Explosive Bolts
 Part #Material Thread
Size 
Type capacity All
Fire 
No
Fire 

Temp

056222 13-8 STAINLESS STEEL PASSIVATED3/8-24 UNF-3A NON-FRAGMENTING TENSILE:: 6000 LBS. MAX. 5.0 AMPS MIN.1A/1W MAX.FOR 5 MINUTES MIN. / BRIDGEWIRE 34°F TO 90°F
057009 PVC 3/8-16 UNC-2A FRAGMENTING TENSILE: 300 LBS. ULTIMATE
TORQUE: 100 INCH OZ. MAX. 
0.5 AMP MIN. 0.2 AMP MAX. FOR 15 SECONDS -20°F TO +140°F
9090044 17-4PH STAINLESS STEEL HEAT TREATED 3/8-16 UNC-2A NON-FRAGMENTING DESIGN TENSILE LOAD: 4000 LBS
ULTIMATE TENSILE LOAD: 7700 LBS.
TORQUE: 190 INCH LBS. MAX. 
7.0 AMPS MIN. 2A/2W MAX. FOR 5 MINUTES MIN. -65°F TO +165°F
057034 416 STAINLESS STEEL7/16-20 UNF-3A NON-FRAGMENTING TENSILE: 8700 LBS.
YIELD, 10000 LBS. ULTIMATE 
4.5 AMPS MIN. 1A/1W MAX. FOR 5 MINUTES MIN.  -82°C(-116°F) TO 83°C (181°F)
05703713-8 STAINLESS STEEL PASSIVATED 1/2-20 UNC-2A NON-FRAGMENTING YIELD STRENGTH: 22000 LBf
ULTIMATE STRENGTH: 23500 LBf
SHEAR STRENGTH: 13500 LBf 
3.5 AMPS MIN. 1A/1W MAX. FOR 5 MINUTES MIN. +100°F MAX.
056003 4130 STEEL, HEAT TREATED CADMIUM PLATED 1/2-20 UNF-3A FRAGMENTING TENSILE: 14000 LBS. MAX.
SHEAR: 8500 LBS. MAX. 
3.5 AMPS MIN. 1A/1W MAX. FOR 5 MINUTES MIN. -65°F TO +165°F
056012  4130 STEEL, HEAT TREATED CADMIUM PLATED 1/2-20 UNF-3A FRAGMENTING DESIGN TENSILE LOAD: 30000 LBS.
DESIGN SHEAR LOAD: 18000 LBS. 
3.5 AMPS MIN. 1.0 AMP MAX -65°F TO +165°F
909000617-4PH STAINLESS STEEL HEAT TREATED 1/2-20 UNF-3A  NON-FRAGMENTINGWORKING TENSILE LOAD: 20000 LBS.
ULTIMATE TENSILE LOAD: 30000 LBS.
WORKING SHEAR LOAD: 5000 LBS.
ULTIMATE SHEAR LOAD: 7500 LBS 
3.5 AMPS MIN. 1A/1W MAX. FOR 5 MINUTES MIN. / BRIDGEWIRE -65°F TO +165°F